Customization: | Available |
---|---|
Warranty: | 1 Year |
Brand: | Raythink |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Thermal Imaging Parameters | |
Detector Type | VOx uncooled focal plane detector |
Spectral Band | 7~8.5μm |
Thermal Sensitivity | ≤20mK(@25°C,F#1.0,25Hz) |
Infrared Resolution | 640×512 |
Pixel Size | 12μm |
Lens Focal Length | 25mm |
Focus Mode | Athermalized prime lens/Electric focusing |
FOV | 17.5°×14° |
IFOV | 0.48mrad |
Palettes | Black-hot/White-hot/Rainbow/Other palettes optional (20 modes in total) |
Visible Light Parameters | |
Sensor | 1/1.8" 4-megapixel CMOS image sensor |
Maximum Image Resolution | 2688×1520 |
Lens Focal Length | 6.4mm~128mm |
Focus Mode | Automatic/Manual/Semi-automatic |
FOV | Horizontal: 59.6°~3.5° |
Gas Parameters | |
Gas Type | Methane (CH4), Sulfur Dioxide (SO2), Freon (R-134a, R-152a) and other gases |
PTZ Parameters | |
Horizontal Range | 360° horizontal continuous rotation |
Vertical Movement | -90°~+90° |
Number of Presets | 256 |
Scan Mode | Preset point/Patrol scan/Pattern scan/Area scanning/Linear scanning |
Temperature Measurement Function | |
Measurement Range | -20ºC~+550ºC |
Measurement Accuracy | ±2°C or ±2% |
Temperature Measurement & Analysis | Support global, point, line, and area temperature measurement rules as well as alarm linkage |
PTZ Function | |
Fire Warning | Supports fire point detection. |
Intelligent Video Taking | Video taking triggered upon alarms or network failures |
Intelligent Alarm | Detects abnormalities, including network cable disconnections, IP address conflicts, memory errors, unauthorized access, and burn warnings, and triggers an alarm in response. |
Intelligent Detection | Supports intelligent analysis of events such as tripwire intrusions and regional intrusions. |
Alarm Linkage | Video taking/Image capture/Email/Linked PTZ/Alarm output |
System Interface | |
Power Supply | 85V~260V AC/24V DC 3A (optional) |
Communication Interface | 1 RJ45 10M/100M adaptive Ethernet port; 1-channel RS485 interface, supporting Pelco protocol. |
Alarm Interface | 1-channel alarm input, 1-channel alarm output |
General Specifications | |
Operating Temperature and Humidity | -40°C~+60°C; <90%RH |
Ingress Protection Rating | IP68 |
Power Consumption | ≤100W (thermostat activated) |
Dimensions | 436×296×406 mm |
Weight | 27kg |
Explosion-proof Mark | Exd IIC T6 Gb/Ex tD A21 IP68 T80℃ |